Anritsu S331L Site Master Handheld Cable and Antenna Analyzer Power Meter

MPN: S331L
Product Brand: Anritsu
Product Condition: Used
Excluding VAT: £2,850.00
Including VAT: £3,420.00
ANRITSU Site Master 2MHz to 4GHz Handheld Cable and Antenna Analyzer with Internal Power Meter (50MHz to 4GHz)
In good condition and in full working order Everything Included Is As Per Photos No Test Cables Included
Included 1 x ANRITSU Sit...
Information
  • ANRITSU Site Master 2MHz to 4GHz Handheld Cable and Antenna Analyzer with Internal Power Meter (50MHz to 4GHz)
In good condition and in full working order
Everything Included Is As Per Photos
No Test Cables Included
Included
1 x ANRITSU Site Master 2MHz to 4GHz Handheld Cable and Antenna Analyzer with Internal Power Meter (50MHz to 4GHz)
1 x Power Supply
1 x Protective Case
1 x Stylus

The Site Master S331L is an all inclusive 1-port cable and antenna analyzer covering the 2 MHz to 4 GHz range, with a built-in InstaCal™ module and a built-in power meter. Standard measurements include:

  • Return Loss
  • VSWR
  • Cable Loss
  • Smith Chart (50/75 ohm selectable)
  • 1-port Phase
  • Distance-to-Fault Return Loss
  • Distance-to-Fault VSWR
  • RF Power (50 MHz to 4 GHz)

VIP Mode; Optical connector inspection with IEC 61300-3-35 based Pass/Fail standard (requires USB Video Inspection Probe G0306A, NOT INCLUDED)

The S331L is the highest value in a rugged, handheld cable and antenna analyzer. The S331L replaces the current value line S331D which is part of the longest running portable cable and antenna analyzer family in history. Utilizing the latest advancements in technology, the S331L has been optimized for field conditions, is easy to use, and has efficient sweep management capabilities. The S331L delivers an entire workday of battery operating time, the most ever offered in a handheld cable and antenna analyzer. With its large outdoor viewable 7" TFT touch screen display, new intuitive GUI, and classic mode that mimic the S331D basic measurement flow, the S331L is very easy to use, and can significantly increase a user's efficiency in the field.

The S331L is for contractors, installers, and wireless service providers, who need an instrument to reduce per site maintenance expenses. Anyone who needs to make basic cable/antenna and power measurements will benefit from the new S331L Site Master. The simple no option configuration and high value pricing make the S331L ideal for tower contractors and can be easily provisioned by stocking distributors and rental companies alike.

The S331L is an all-inclusive instrument with a built-in InstaCal™/Power Meter module. The S331L arrives fully capable of measuring:

1-port RF Cable and Antenna testing 2 MHz to 4 GHz such as:

  • Cellular
  • Public Safety
  • Radio and TV broadcasting
  • Aerospace and defense

Measurements include:

  • Return Loss
  • VSWR
  • Cable Loss
  • Smith Chart (50/75 ohm selectable)
  • 1-port Phase
  • Distance-to-Fault Return Loss
  • Distance-to-Fault VSWR
  • RF Power (50 MHz to 4 GHz)

Specifications:

Measurements
Measurements VSWR
Return Loss
Cable Loss (One Port)
Distance-to-Fault (DTF)
Return Loss Distance-to-Fault (DTF) VSWR
Setup Parameters-Classic Mode
Measurement display Single Display with independent markers
Frequency F1/F2
DTF D1/D2, DTF Aid, Cable Loss, Propagation Velocity, Cable type
Windowing Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Amplitude Top, Bottom Auto Scale, Full Scale
Sweep Data Points, Run/Hold, Single/Continuous, RF Immunity (High/Low)
Data Points 130, 259, 517, 1033
Markers Markers 1 to 6 (On/Off), Delta Markers 2 to 4 (Ref M1), Marker to Peak/Valley, Marker Table, Marker 5 (Peak/Valley between M1 & M2), Marker 6 (Peak/Valley between M3 & M4)
Traces Copy Trace To Memory, Trace Display, Trace Math
Limit Line On/Off, Edit Value, Limit Alarm, Pass/Fail On/Off, Limit Preset
Calibration Cal Type OSL/Standard/FlexCal™/InstaCal™
Save/Recall Setups, Measurements, Screen Shots
Setup Parameters-Advanced Mode
Measurement Display Single Display with independent markers
Frequency Start Frequency (F1), Stop Frequency (F2)
DTF Start Distance (D1), Stop Distance (D2), Units m/ft, DTF Aid, Cable List, Cable Loss, Propagation Velocity
Windowing Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Amplitude Top, Bottom, Auto Scale, Full Scale
Sweep Data Points, Run/Hold, Single/Continuous, RF Immunity (High/Low)
Data Points 130, 259, 517, 1033
Markers Markers 1 to 8 (On/Off), Delta Markers 2 to 8 (Ref M1), Marker to Peak/Valley, Marker Table, Marker 5 & 7 (Peak/Valley between M1 & M2), Marker 6 & 8 (Peak/Valley between M3 & M4)
Traces Copy Trace to Memory, Trace Display, Trace Math
Limit Line On/Off, Edit Value, Limit Alarm, Pass/Fail On/Off, Limit Preset
Calibration Cal Type OSL/Standard/FlexCal™/InstaCal
Save/Recall Setups, Measurements, Screen Shots
Frequency
Frequency Range 2 MHz to 4 GHz
Frequency Accuracy ± 5 ppm @ 23 °C ± 3 °C
Frequency Resolution 1 kHz
Power
Output Power +3 dBm, typical
Interference Immunity
On-Channel +17 dBm outside calibrated sweep range
On-Frequency +13 dBm within calibrated sweep range
Measurement Speed
Return Loss ≤ 1.50 ms/data point, RF immunity low, typical
Distance-to-Fault ≤ 1.75 ms/data point, RF immunity low, typical
Return Loss
Measurement Range Resolution 0 to 60 dB 0.01 dB
VSWR
Measurement Range 1 to 65
Resolution 0.01 dB
Distance-to-Fault
Vertical Range Return Loss 0 to 60 dB
Vertical Range VSWR 1 to 65
Fault Resolution (meters) (1.5 x 108 x vp)/ΔF (vp = propagation velocity, ΔF is F2 - F1 in Hz)
Horizontal Range (meters) 0 to (Data Points - 1) x Fault Resolution, to maximum of 1500 meters (4921 feet)
Measurement Accuracy
Corrected Directivity ≥ 38 dB, InstaCal™ calibration
≥ 42 dB, OSL calibration (OSLN50-1, OSLNF50-1)
General Specifications
Setup Parameters
System Info Status, Battery
System Setups Date/Time, Language, Display/Audio
Date/Time Day, Month, Year, Time
Language English, French, German, Italian, Spanish, Russian, Portuguese, Japanese, Korean, Chinese
Display/Audio Brightness, Color Schemes, Screen Shot Settings, Volume
Diagnostics Self Test
Preset Preset, Reset
Reset Factory Reset, Master Reset, Update Firmware
File Save, Recall, File Management
File Management Rename, Create Folder, Copy, Paste, Delete, Navigation
Navigation Top, Bottom, Page Up, Page Down
Save Measurement (*.dat), Setup (*.stp), Screen Shot (*.png)
Internal Trace/Setup Memory > 1000 files (files may be traces, setups, screen shots, or any combination)
External Trace/Setup Memory Limited only by size of USB Flash drive
Connectors
RF Out/Reflect In Type N, female, 50 Ω, Maximum Input +23 dBm, ± 50 VDC
InstaCal™/Power Meter Type N, male, 50 Ω, Maximum Input +27 dBm, ± 45 VDC (Damage Level)
External Power 5.5 mm barrel connector, 11 to 14 VDC, < 3.0 A
USB Port USB 2.0 Type A (two ports)
USB Interface Type mini-B, Connect to PC for data transfer
Display
Type TFT Resistive Touch Screen
Size 7.0" daylight viewable color LCD
Resolution 800 x 480
Battery
Type Li-Ion
Battery Operation > 8.0 Hours typical (70 % brightness setting, continuous usage)
Electromagnetic Compatibility
European Union CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and Low Voltage Directive 73/23/EEC, 93/68/EEC
Interference EN 61326-1
Emissions EN 55011
Immunity EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-11
Australia and New Zealand C-tick N274
Safety
Safety Class EN 61010-1 Class 1
Product Safety IEC 60950-1 when used with Company supplied Power Supply
Environmental
Operating Temperature -10 °C to +55 °C
Maximum Humidity 95 % non-condensing
Altitude 4600 meters
Shock MIL-PRF-28800F Class 2
Storage -40 °C to 71 °C
Size and Weight
Size 250 mm x 177 mm x 61 mm (10.0 in x 7.1 in x 2.4 in)
Weight < 2.0 kg (4.4 lb), including battery

 

SL 289602
Specifications
  • MPN:
    S331L

To request a price please fill out the form below...


Close