Fluke 1743 Power Quality Logger L1 L2 L3 Phase Analyser Energy Meter Test Kit
Click the image to expand
Fluke 1743 Power Quality Logger L1 L2 L3 Phase Analyser Energy Meter Test Kit Fluke 1743 Power Quality Logger L1 L2 L3 Phase Analyser Energy Meter Test Kit Fluke 1743 Power Quality Logger L1 L2 L3 Phase Analyser Energy Meter Test Kit Fluke 1743 Power Quality Logger L1 L2 L3 Phase Analyser Energy Meter Test Kit

Fluke 1743 Power Quality Logger L1 L2 L3 Phase Analyser Energy Meter Test Kit

Brand: Fluke
MPN:Fluke 1743
Product Condition: Used
Quantity:
Excluding VAT: £1,140.00
Including VAT:£1,368.00
Fluke 1743 Power Quality Analyser Kit Test Leads International Adapters & Case

Model No: Fluke 1743

In Good Condition and Full working Order

Included:

  • 1 x Fluke 1743 Power Quality Analyser
  • 1 x Data Lead
  • 1 x User Manual
  • 2 x Disc's
  • 4 x International IEC Adapters
  • 1735/43/44/45 Lead
General Data
Intrinsic error Refers to the reference conditions and is guaranteed for two years
Quality system developed, designed, and manufactured according to DIN ISO 9001
Reference conditions 23°C ±2 K; 74°F ±2 K , Vm = 230 V ±10%, 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
Phase sequence L1, L2, L3
Interval length 10 minutes
Wye connection (L1, L2, L3 to N)
Power supply 88 V ... 265 VAC
Environment conditions Working temp. range -10°C to 55°C; 14°F to 131°F
Operating temp. range 0°C to 35°C; 32°F to 95°F
Storage temp. range -20°C to 60°C; -4°F to 140°F
Reference temp. range 23°C ±2 K; 74°F ±2 K
Relative humidity Class C2 acc. IEC 60654-1
Housing robust, fully insulated housing and accessories
Protection type IP65 as per EN 60529
Safety IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation
Type test voltage 5.2 kV rms, 50 Hz / 60 Hz, 5 s
EMC Emission IEC/EN 61326-1, EN55022
Immunity IEC/EN 61326-1
Voltage and Current Measurement
Input voltage Input range VI P-N max 480 VAC
Input range VI P-P max 830 VAC
Max. overload voltage 1.2 VI
Input range selection By job programming
Connections P-P or P-N, 1- or 3-phase
Nominal voltage VN ≤ 999 kV with PTs and ratio
Input resistance App. 820 kΩ per chan. Lx-N Single phase (L1 or A, L2 or B, L3 or C connected): app. 300 kΩ
Intrinsic uncenrtainty 0.1% of VI
Voltage transformer Ratio: < 999 kV / VI
Ration selection By job programming
Current input with Flexi Set Input ranges II L1 or A, L2 or B, L3 or C, N 15 A / 150 A / 1500 A / 3000 A AC
Measuring range 0.75 A … 3000 A AC
Intrinsic uncertainty < 2% of II
Position influence Max. ±2% of measured value - for distance conductor to meas. head > 30 mm
Stray field influence < ±2 A AC for Iext = 500 A AC and distance to measuring head > 200 mm
Temperature coefficient < 0.05% / K
Current transformer Ratio ≤ 999 kA / II
Ratio selection By job programming
Connection 3-phase, 3-phase +N, 2 phase L1 or A and L3 or C (2 W-meter-method) 7 pole connector
Current input for clamp Input ranges II L1 or A,
L2 or B, L3 or C, N
0.5 V nominal (for II) 1.4 Vpeak
Intrinsic uncertainty < 0.3% of II
Max. overload 10 VAC
Input resistance App. 8.2 kΩ
Current transformer Ratio Ω 999 kA / II
Power systems Delta, 2-Element Delta, Wye, Single Phase, Split Single Phase
Logger
Power supply Functional Range 88 V to 660 V absolute, 50 Hz / 60 Hz
100 V to 350 VDC Internal fuse: 630 mA T
Power consumption 5 Watts
Ride through 3 sec Capacitor
Fuse Power supply fuse can be replaced in service facility only. Supply can be connected in parallel to measuring inputs (up to 660 V)
Display, indicators LEDs for status and voltage levels
Memory Capacity 8 MB Flash-EPROM
Intervals A function > 12000 intervals for > 85 days with 10 min intervals
P function > 30000 intervals for > 212 days with 10 min intervals
Events > 13000
Memory model linear, circular
Interface RS 232, 9600...115 000 Baud, automatic Baud rate selection, 3-wire communication
Dimensions 170 x 125 x 55 mm (69 x 51 x 22 in)
Weight approx. 2 kg
Measurement A/D converter 16 bit, sample rate: 10.24 kHz
Anti-aliasing filter FIR-Filter, fc = 4.9 kHz
Frequency response Uncertainty < 1% of Vm for 40 Hz to 2500 Hz
Interval length 1, 3, 5, 10, 30 s, 1, 5, 10, 15, 60 minutes
Averaging time for Min/max values ½, 1 mains period, 200 ms, 1, 3, 5 s
Time base Resolution: 10 ms (at 50 Hz), deviation: 2 s/day at 23°C; 74°F ±2 K

VAT IS NOT PAYABLE BY PURCHASERS OUTSIDE THE European Union (EU) AND by purchasers in the EU (excluding UK) who are VAT registered - International Delivery is with UPS